Low Pressure Reducing Valve



Product Code: D50NZ
Available in 37kPa and 75kPa

 Thermosyphon loop no longer required on side entry cylinders All dimensions are available as high-resolution, printable files. To download and print, simply click on the picture below and a larger, printable version will be downloaded. To print, press Ctrl-P for a PC or Command-P for a Macintosh and your dimensions will be output.



 Pressure compensated to give constant low pressure setting regardless of inlet pressure increases
 Pressure settings (Nominal):
 3.7m and 7.6m. Fully adjustable
 Flow rates from Reducing Valve outlet:

Inlet Pressure Valve Settings
(Constant) 3.7m 7.6m
275kPa 38 L/min 40 L/min
350kPa 42 L/min 45 L/min
410kPa 44 L/min 48 L/min
 Guaranteed for five years
 Complies with NZS 4608