| Features |
 |
Large flow passages |
 |
Foolproof design reduces chance of disabling through closing off vent holes |
 |
Far Exceeds the requirements of AS2845.1 for flow capacity and pressure loss |
| Specific Installantion Requirements |
 |
Shall not, under normal operation, be subject to continuous pressure |
 |
To be vented to atmosphere |
 |
If the device is removed, another device of equal or greater hazard rating to be installed in the water supply |
 |
Have no isolation valves located downstream of the vacuum breaker. (This includes solenoids, shut off devices and automatic valves)
|
 |
Not to be subject to freezing temperatures |
 |
For use with irrigation sprinkler heads less than 150mm above ground level. The AquaGuard should be located 450mm above the highest outlet. Not to be used with injection systems. |